Daikin FTXG35CVMBS Specifiche Pagina 156

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 155
Si04-402 Indoor Unit
Removal Procedure 147
1.12 Removal of Fan Rotor and Fan Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the right side
plate.
1
Loosen the 2 screws.
2
Remove the right side
plate.
2. Remove the motor cover.
1
Loosen the 2 screws
and remove the motor
cover.
Vedere la pagina 155
1 2 ... 151 152 153 154 155 156 157 158 159 160 161 ... 193 194