Daikin FHQ50BVV1B Manuale di Installazione Pagina 1

Navigare online o scaricare Manuale di Installazione per Climatizzatori a split Daikin FHQ50BVV1B. Daikin FHQ50BVV1B Installation manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 30
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
SPLIT SYSTEM Air Conditioners
INSTALLATION MANUAL
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L’INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA DUDA.
PRIMA DELL’INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ
ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ПЕРЕД НАЧАЛОМ МОНТАЖА ВНИМАТЕЛЬНО ОЗНАКОМЬТЕСЬ С ДАННЫМИ
ИНСТРУКЦИЯМИ. СОХРАНИТЕ ДАННОЕ РУКОВОДСТВО В МЕСТЕ, УДОБНОМ ДЛЯ
ОБРАЩЕНИЯ В БУДУЩЕМ.
MODELS
(Ceiling suspension type)
FHQ35BVV1B FHQ35BWV1B
FHQ50BVV1B FHQ50BWV1B
FHQ60BVV1B FHQ60BWV1B
FHQ71BVV1B
FHQ100BVV1B
FHQ125BVV1B
English
Deutsch
Français
Español
Italiano
Nederlands
Portugues
00_CV_3PN06588-4M.fm Page 1 Thursday, October 20, 2011 4:37 PM
Vedere la pagina 0
1 2 3 4 5 6 ... 29 30

Sommario

Pagina 1 - INSTALLATION MANUAL

SPLIT SYSTEM Air ConditionersINSTALLATION MANUALREAD THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REF

Pagina 2 - Machinery Safety 98/37/EC

8 English5. INDOOR UNIT INSTALLATIONIt may be easier to attach accessory parts before installing the indoor unit. Therefore, please also read the inst

Pagina 3 - 1. SAFETY PRECAUTIONS

English 96. REFRIGERANT PIPING WORK〈For refrigerant piping of outdoor units, see the installation manual attached to the outdoor unit.〉 〈Execute heat

Pagina 4

10 EnglishNot recommendable but in case of emergencyYou must use a torque wrench but if you are obliged to install the unit without a torque wrench, y

Pagina 5 - 2. BEFORE INSTALLATION

English 11• Make absolutely sure to execute heat insulation works on the pipe-connecting section after checking gas leakage by thoroughly studying the

Pagina 6 - 2-3 NOTE TO THE INSTALLER

12 English(1) For piping facing back.• Remove the rear penetration lid and set the piping. (Refer to Fig. 14.16)(2) For piping facing up.• When settin

Pagina 7 - ∗≥30 ∗≥30

English 137. DRAIN PIPING WORK(1) Carry out the drain piping.• Make sure piping provides proper drainage.• You can select whether to bring the drain p

Pagina 8

14 English• Insulate the clamp bracket and drain hose from the bottom using the included sealing pad (8). (Refer to Fig. 21)• Be sure to insulate all

Pagina 9

English 158. WIRING EXAMPLEFor the wiring of outdoor units, refer to the installation manual attached to the outdoor units.Confirm the system type.• P

Pagina 10 - 5. INDOOR UNIT INSTALLATION

16 EnglishNOTE1.All transmission wiring except for the remote controller wires is polarized and must match the terminal symbol.2. In case of group con

Pagina 11 - 6. REFRIGERANT PIPING WORK

English 17Connection of wiring between units and for the remote control cord (Refer to Fig. 27)• Wiring between unitsHolding the control box lid, loo

Pagina 12

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 JapanDAIKIN INDUSTRIES, LTD.EN60335-2-40,3P104327-1FShinri SadaManager Quality Con

Pagina 13

18 EnglishObserve the notes mentioned below when wiring to the terminals.Tightening torque for the terminal screws.• Use the correct screwdriver for t

Pagina 14

English 1910. FIELD SETTINGS(1) Make sure the control box lids are closed on the indoor and outdoor units.(2) Field settings must be made from the rem

Pagina 15 - 7. DRAIN PIPING WORK

20 EnglishWhen using wireless remote controllers• When using wireless remote controllers, wireless remote controller address setting is necessary. Ref

Pagina 16

English 2110-7 Two remote controllers control (Controlling 1 indoor unit by 2 remote controllers)• When using 2 remote controllers, one must be set to

Pagina 17 - 8. WIRING EXAMPLE

22 EnglishPRECAUTIONS1. Refer to “11-2 HOW TO DIAGNOSE FOR MALFUNCTION” if the unit does not operate properly.2. After completing the test run, press

Pagina 18 - 9. ELECTRIC WIRING WORK

English 2311-3 Malfunciton code list• For plases where the Malfunction code is left blank, the “ ” indication is not displayed. Though the system cont

Pagina 19

24 EnglishNOTE1. Abnormal stop is applied depending on the model or condition.J9 Gas piping thermistor malfunction (cooling) (outdoor) (NOTE 1)JA Disc

Pagina 20 - Attach insulation sleeve

English 25CAUTION• Refer to “b. Items to be checked at time of delivery” on page 4 upon completion of the test run and makesure that all the items are

Pagina 21 - 10. FIELD SETTINGS

26 English3D074574-1 FHQ35 • 50 • 60 BVV1B, FHQ35 • 50 • 60BWV1B: CONNECTOR DISCRIMINATION COLOUR FOR COMPONENTS.: CONNECTOR COLOUR FOR COMPONENTS.: C

Pagina 22 - Indoor unit 3

English 27, : CONNECTOR3D043825-1B FHQ71 • 100 • 125 BAV3B, FHQ71 • 100 • 125 BUV1B, FHQ71 • 100 • 125BVV1BA1PC1HAPKARKPRM1FM1SQ1MR1TR2TS1

Pagina 23 - 11. TEST OPERATION

English 1FHQ35BVV1BFHQ50BVV1BFHQ60BVV1BFHQ71BVV1BFHQ100BVV1BFHQ125BVV1BFHQ35BWV1BFHQ50BWV1BFHQ60BWV1BSPLIT SYSTEMAir ConditionerInstallation manualCON

Pagina 24

(1111)HT3PN06588-4M EM11A06200_CV_3PN06588-4M.fm Page 2 Thursday, October 20, 2011 4:37 PM

Pagina 25 - 11-3 Malfunciton code list

2 English• Be sure to use only the specified accessories and parts for installation work. Failure to use the specified parts may result in the unit fa

Pagina 26

English 32. BEFORE INSTALLATION• When moving the unit while removing it from the carton box, be sure to lift it by holding on to the four lifting lugs

Pagina 27 - 12. WIRING DIAGRAM

4 EnglishNOTE• If you wish to use a remote controller that is not listed in “Table 1” on page 3, select a suitable remote con-troller after consulting

Pagina 28 - WIRING DIAGRAM

English 53. SELECTING INSTALLATION SITE(1) Select an installation site where the following conditions are fulfilled and that meets your cus-tomer’s ap

Pagina 29

6 English4. PREPARATIONS BEFORE INSTALLATION(1) Relation of holes for indoor unit, suspension bolt position, piping and wiring.(2) Make holes for susp

Pagina 30 - 3PN06588-4M EM11A062

English 7(3-3) Remove the hanger brackets.• Loosen the 2 bolts (M8) used to attach the hanger brackets which are on each side (4 places left and right