Daikin IM-820 Specifiche Pagina 67

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 97
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 66
59
! In combination with exclusive driver, it can have a high response and
suits the closed loop controls of position , speed and pressure for a
main machines actuator. (Frequency response: 130Hz/-3dB±10%
amplitude)
! Since a proportional solenoid directly drives a spool, the leak volume
can keep a least value compared to a nozzle flapper type servo
valve.
! When an exclusive driver is used, it becomes all port block (fail
safefunction) at power off.
Direct type servo valve
Specifications
Features
Note) !1 The rated flow rate is the one at 1 land differential pressure: P = 3.5 MPa {35kgf/cm
2
}.
Solenoid pilot type servo valve
Note) 1 The rated flow rate is the one under the conditions bellow.
%%" Servo type 3,5 : 1 land differential pressure P = 3.5 MPa {35kgf/cm
2
}
(For servo type 5, it is a value when P1A and P2B join together.)
%%" Servo type 4 : Valve differential pressure P = 7MPa {70kgf/cm
2
}
Features
Specifications
! Suits a closed loop control of position, speed and pressure of
main machines actuator.
! As a pilot valve adopts large sized orifice nozzle for a nozzle
flapper type,anti-contaminant characteristics is strengthen.
! A driver is mounted on a valve.
! As option with pressure sensor is provided, closed loop control
can be easily performed.
Model code
KSPS-G02-1*-10
KSPS-G02-2*-10
KSPS-G02-4*-10
KSPS-G02-1*-10-E
KSPS-G02-2*-10-E
KSPS-G02-4*-10-E
Max. operating
pressure
MPa {kgf/cm
2
}
35 {350}
Rated flow
rate 1
L
/min
10
20
40
10
20
40
T-port permissible
back pressure
MPa {kgf/cm
2
}
2.5 {25}
16 {160}
Pressure gain
1 type: 2% or less
2 type: 4% or less
Hysteresis resolution
power repeated
characteristics
1% or less
Solenoid rated
voltage
v
DC12
Max.
current
mA
1700
Weight
kg
2.5
JIS symbols
Model code
JSES-G03-3-20
JSES-G03-41-20
JSES-G03-42-20
JSES-G03-43-20
JSES-G03-5-20
JSES-G04-3-20
JSES-G04-4-20
Max. operating
pressure
MPa {kgf/cm
2
}
21 {210}
Rated flow
rate 1
L
/min
190
45
95
190
360
540
500
Drain line
permissible back
pressure
MPa {kgf/cm
2
}
1.4 {14}
Nom. Dia.
3/8
1/2
Hysteresis resolution
power repeated
characteristics
0.5% or less
Pilot valve
Supply pressure
MPa {kgf/cm
2
}
3~5 {30~50}
3~7 {30~70}
Required
flow rate
L/min
2.7~3.5
4.2~6.5
Saturated
amperes
mA
250
Weight
kg
9.9
11.5
JIS symbols
3-way valve
4-way valve
5-way valve
Vedere la pagina 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 96 97