Daikin FHQ71BUV1B Manuale Utente

Navigare online o scaricare Manuale Utente per Climatizzatori a split Daikin FHQ71BUV1B. Split Sky Air Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 27
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
FHQ-BU
Ceiling
Suspended Unit
technical data
Split
Sky Air
air conditioning systems
Vedere la pagina 0
1 2 3 4 5 6 ... 26 27

Sommario

Pagina 1 - Suspended Unit

FHQ-BUCeiling Suspended Unittechnical data SplitSky Airair conditioning systems

Pagina 2 - Split - Sky Air

3Dimensional drawingsFHQ35BUView from the front780 From the floor side 2500 or more(Required space)Note:1. Location of unit’s name plate: bottom of fa

Pagina 3 - TABLE OF CONTENTS

FHQ60BUView from the front780 From the floor side 2500 or more(Required space)Note:1. Location of unit’s name plate: bottom of fan housing inside the

Pagina 4 - Optional Optional 2 steps

FHQ100BUView from the front780 From the floor side 2500 or more(Required space)Note:1. Location of unit’s name plate: bottom of fan housing inside the

Pagina 5 - Specifications

4Piping diagramsO Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe PSpinned pipeIndoor heat exchangerField pipingJ

Pagina 6

5Wiring diagrams3D037842CFHQ35∼60BU1-RED, 2-WHITE, 3-BLACKA1P Printed circuit boardC1R Capacitor (M1F)F1U Fuse(F5A 250V)HAP Light emitting diode (serv

Pagina 7

4D043825AFHQ71,100,125BU1-RED, 2-WHITE, 3-BLACKA1P Printed circuit boardC1R Capacitor (M1F)HAP Light emitting diode (service monitor green)KAR Magneti

Pagina 8

6Sound level6-1Sound level dataOctave band sound pressure levelOctave band sound pressure levelOctave band center frequency (Hz) Octave band center fr

Pagina 9

FHQ71BUFHQ125BUOctave band center frequency (Hz)Octave band center frequency (Hz)Octave band sound pressure levelOctave band sound pressure levelOctav

Pagina 10 - Dimensional drawings

7Air flow patternsFHQ35∼50BUCooling - air velocity distributionAir flow direction: horizontalFHQ35∼50BUCooling - air temperature distributionAir flow

Pagina 11

FHQ35∼50BUHeating - air velocity distributionAir flow direction: 45° (downward)FHQ35∼50BUHeating - air temperature distributionAir flow direction: 45°

Pagina 12

Split - Sky AirEEDE05-1/3 • 05/2005Prepared in Belgium by Goekint GraphicsZandvoordestraat 300B - 8400 Ostend BelgiumSpecifications are subject to cha

Pagina 13 - Piping diagrams

FHQ60-71BUCooling - air velocity distributionAir flow direction: horizontalFHQ60-71BUCooling - air temperature distributionAir flow direction: horizon

Pagina 14 - Wiring diagrams

FHQ60-71BUHeating - air velocity distributionAir flow direction: 45° (downward)FHQ60-71BUHeating - air temperature distributionAir flow direction: 45°

Pagina 15

FHQ100BUCooling - air velocity distributionAir flow direction: horizontalFHQ100BUCooling - air temperature distributionAir flow direction: horizontal4

Pagina 16 - Sound level

FHQ100BUHeating - air velocity distributionAir flow direction: 45° (downward)FHQ100BUHeating - air temperature distributionAir flow direction: 45° (do

Pagina 17

FHQ125BUCooling - air velocity distributionAir flow direction: horizontalFHQ125BUCooling - air temperature distributionAir flow direction: horizontal4

Pagina 18 - 4D028550

FHQ125BUHeating - air velocity distributionAir flow direction: 45° (downward)FHQ125BUHeating - air temperature distributionAir flow direction: 45° (do

Pagina 19 - 4D028554

8Accessories8-1Optional accessoriesFHQ35∼60BUName of option FHQ∼BUV1B35 50 60Replacement long-life filter KAFJ501D56 KAFJ501D80Drain up kit KDU50M60VE

Pagina 20 - 4D028551A

9Control systems9-1Wired remote control6.5 x 9 (Round end slit)Cover openCover closed5 x 7 (Round end slit)HoleJ55 x 10 (Round end slit)3TW23651-2BRC1

Pagina 21 - 4D028555A

TABLE OF CONTENTSFHQ-BU1 Features ... 22 Specifications...

Pagina 22 - 4D028552A

1Features+ Leaves maximum floor and wall space for furniture, decorationand fittings+ Compact casing (only 960mm width)+ Extremely quiet in operation

Pagina 23 - 4D028556A

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FHQ35BUV1B FHQ50BUV1B FHQ60BUV1BNOMINAL INPUT Cooling kW - - -Heat

Pagina 24 - 4D028553A

NOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FHQ71BUV1B FHQ100BUV1B FHQ125BUV1BNOMINAL INPUT Cooling kW - - -Heating kW 0.117

Pagina 25 - 4D028557A

TECHNICAL SPECIFICATIONSFor indoor units only:INDOOR UNITS FHQ35BUV1B FHQ50BUV1B FHQ60BUV1BDIMENSIONS Unit H mm 195W mm 960 1,160D mm 680WEIGHT Unit k

Pagina 26 - Accessories

ELECTRICAL SPECIFICATIONSFor indoor units only: FHQ35BUV1B FHQ50BUV1B FHQ60BUV1BCURRENT Nominal running currentcooling/heatingA See chapters RS-B + RK

Pagina 27 - Safety device settings

ELECTRICAL SPECIFICATIONSFor indoor units only: FHQ71BUV1B FHQ100BUV1B FHQ125BUV1BCURRENT Nominal running currentcooling/heatingA See chapter RR-B7, R

Commenti su questo manuale