Outdoor Unit SiBE12-713
300 Removal Procedure
1.3 Removal of the PCB
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the service PCB ★ Illustrations are for 3 room
model.
1
External appearance of
the service PCB and
the terminal board.
2
Loosen the 1 screw of
the terminal board and
open it.
3
Disconnect the
connector [S52] and
[S102] from the service
PCB.
Commenti su questo manuale